Make your swim spa installation more flexible

swim spa

Environmental
Operating temperature: 0°C (32°F) to 50°C (122°F)
Storage temperature: -20°C (-4°F) to 85°C (185°F)
Humidity: up to 85% RH, non condensing
Water ingress protection: IPx5

Mechanical
Weight: 4.76 kg (10.5 lbs)
Dimensions (W x H x D):
Chassis: 441.5 x 298.5 x 129 mm (17.38" x 11.75" x 5.1")

Swim Spas UL/CSA electrical specifications
Voltage Input:
Current Input:
120 / 240 VAC
2 x 48 A or 1 x 60 A
Master in.xe

OutputVoltageMaximum Current
Pump 1 (2 speeds) High120/240V20 FLA/70 LRA
Pump 1 (2 speeds) Low120/240V 15 FLA/60 LRA
Pump 2 (1 speed)240V15 FLA/60 LRA
Blower120/240V 6 FLA/10 A
Circ. pump 120/240V 6 FLA/10 A
Direct (audio)120/240V 10 A
Light12V1 A
Heater240V4.0 kW

**The total maximum amperage for blower, circ pump and Direct cannot exceed 12 Amps

Slave in.xe

OutputVoltageMaximum Current
Pump 3 (1 speed)120/240V10 FLA/60 LRA*
Pump 4 (1 speed)240V15 FLA/60 LRA
Pump 5 (1 speed)120/240V10 FLA/60 LRA
Light 3120/240V 6 FLA/10 A
Ozone120/240V 6 FLA/10 A
Direct (other)120/240V 6 FLA/10 A
Light 212V1 A
Heater240V4.0 kW

*To install pump 5, an in.split cable is required. If the pump 5 is not installed, the pump 3 can be 20 FLA and a two speed pump. If both pump 3 & pump 5 are installed, then each individual pump cannot exceed 10 FLA (max total combined of 20 FLA).

**The total maximum amperage for light 3, Ozone and Direct cannot exceed 12 Amps

heat.wav ratings

Voltage:240 VAC, 60 Hz
Current:17 A resistive (4 kW at 240V)
Flow rate:
 
Minimum of 18 GPM is required
 
UL/CSA Standards

UI 1563 Fifth ed.
CSA No. 22.2-218.1-M89

Swim Spas TUV electrical specifications
Voltage Input:
Current Input:
230 / 400 VAC 3 phase or single
3 x 20 A max or 1 x 60 A
Master in.xe

OutputVoltageMaximum Current
Pump 1 (2 speeds) 230V15 FLA/60 LRA
Pump 2 (1 speed) 230V15 FLA/60 LRA
Blower230V6 FLA/10 A
Circ. pump230V6 FLA/10 A
Direct (audio)230V 10 A
Light12V1 A
Heater230V3.8 kW
 

**The total maximum amperage for blower, circ pump and Direct cannot exceed 12 Amps

Slave in.xe

OutputVoltageMaximum Current
Pump 3 (1 speed)230V7.5 FLA/60 LRA*
Pump 4 (1 speed)230V15 FLA/60 LRA
Pump 5 (1 speed)230V7.5 FLA/60 LRA
Light 3230V6 FLA/10 A
Ozone230V 6 FLA/10 A
Direct (other)230V6 FLA/10 A
Light 212V1 A
Heater230V3.8 kW

*To install pump 5, an in.split cable is required. If the pump 5 is not installed, the pump 3 can be 15 FLA and a two speed pump. If both pump 3 & pump 5 are installed, each individual pump cannot exceed 7.5 FLA (max total combined of 15 FLA).

**The total maximum amperage for light 3, Ozone and Direct cannot exceed 12 Amps

heat.wav ratings

Voltage:230 VAC, 50 Hz
Current:
 
 
8,7 A resistive (2 kW at 230V)
5,7 A resistive (1.3 kW at 230V)
16 A resistive (3.8 kW at 230V)
Flow rate:Minimum of 18 GPM is required
TUV Standards

European:
EN/IEC 60335-1: 2002/2001
EN/IEC 60335-2-60: 2003/2002 (incl. Corr. & Am up to 2004)
EN55014-1, EN55014-2
EN61000-3-2, EN61000-3-3
Australia:
AS/NZS 3136:2001 +A1 +A2
AS/NZS 3100:2002 + A1+A2+A3