Logo GeckoLogo GeckoLogo Gecko
Creating products. Building relationships.

Our products

HOME   /   PROFESSIONAL   /   PRODUCTS   /   IN.XE

innovative entry level spa pack platform

Main features and specification summary

in.xe
Main feature summary:
in.put
in.put
new input terminal bloc

In.xe's cable bay was designed to ease wire insertion. Its terminal bloc has more room to insert wires. Tighter input connection reduces heat generated for increased component lifetime.

in.axess
in.axess
board access prevention

Only serviceable parts, terminal bloc, fuses, heater and probe connectors, are made accessible to service technicians. Electronic components are protected in separate and inaccessible compartments.

in.seal
in.seal
watertight protection

In.seal provides extra level of protection against water infiltration. Connectors and power box are designed to be watertight and no water can be in direct contact with electrical components. (IPX5)

in.link
plugs and connectors

Totally waterproof, in.link plugs and connectors are designed to ensure that all cables of equipment used to make a spa work properly are well connected at their intended connection port, eliminating any risk of mis-wiring.

in.flo
in.flo
solid state monitoring

In.flo is an all-electronic dry-fire protection of in.xe's heat.wav heater. In.flo eliminates the burden of adjustments, calibrations and failures associated to usual water flow sensors.

in.kin
in.kin
kinetic heat monitoring

In.xe design includes in.kin, a contactor that protects spas and spa users against water overheat. In.kin is the industry's first and only true kinetic heat protection because it monitors all pump outputs, not just the "heating" pump.

in.t.cip
in.t.cip
water temp. algorithm

In.xe also monitors water temperature through in.t.cip, our breakthrough software algorithm that calculates optimal time to start pumps and get water temperature readings.

in.stik
in.stik
software auto-uploader

In.stik is another cool in.xe feature, a pen drive software auto-uploader with an in.link connector. In.stik connects to in.xe and contains software to program or configure its system. In.xe executes the data upload and update automatically.

Specifications review:

in.xe UL/CSA electrical specifications

Input rating:

Or:
120/240 VAC nominal (+ 5/- 10 %)
(2 lines required with neutral) 48 A Max,
120 VAC nominal only (+ 5/- 10%)
single line with neutral) 16 A Max,
60Hz nominal (+ 1. 5 / -1.0 Hz).

Output ratings:

Output
Out 1

Out 2
Out 3
Out 4
Out 5
L1
CO
C1
Voltage
120/240V
120/240V
240V
120/240V
120/240V
120/240V
12VAC
Maximum Current
20 FLA/70 LRA (in-rush)
15 FLA/60 LRA (in-rush)
15 FLA/60 LRA (in-rush)
10 A
6 FLA/10 A
10 A (always ON)
1 A
Typical Device
Pump 1 High Speed
Pump 1 Low Speed
Pump 2
(CP)/Blower
Ozone Generator
Audio/Video device
Light
Communications port (in.stik)
Tub side controller

heat.wav ratings:

Voltage:
Current:

Flow rate:
120 or 240 VAC, 60 Hz
17A resistive (4 kW at 240V)
8.5 A resistive (1kW at 120v)
Minimum of 18 GPM is required

in.xe.ce TUV electrical specifications

Input rating:

Or:
230/400 VAC nominal (+ 5/- 10 %)
(2-phase system) 20 A Max per phase
230 VAC nominal (+ 5/- 10 %)
(single-phase system) 40 A Max
50 Hz nominal (+ 1. 5 / -1.0 Hz)

Output ratings:

Output
Out 1
Out 2
Out 3
Out 4
Out 5
L1
CO
C1
Voltage
230V
230V
230V
230V
230V
12VAC
Maximum Current
15 FLA/60 LRA (in-rush)
15 FLA/60 LRA (in-rush)
6 FLA/10 A
6 FLA/10 A
10 A (always ON)
1 A
Typical Device
Pump 1 Hi & Low
Pump 2
(CP)/Blower
Ozone Generator
Audio/Video device
Light
Communications port (in.stik)
Tub side controller

heat.wav ratings:

Voltage:
Current:

Flow rate:
230 VAC, 50 Hz
8.7 A resistive (2kW at 230v)
5.7 A resistive (1.3 kW at 230v)
16.5 A resistive (3.8 kW at 230v)
Minimum of 18 GPM is required

Environmental:

Operating temperature (*)
North American model in.xe:
0°C (32°F) to 60°C (140°F) for Pump 1 up to 15 A
0°C (32°F) to 50°C (122°F) for Pump 1 up to 20 A
European model in.xe.ce:
for single-phase system (32 A Max) or 2-phase (2 x 16 A)
0°C (32°F) to 60°C (140°F)
for single-phase system (40 A Max) or 2-phase (2 x 20 A)
0°C (32°F) to 50°C (122°F)
(*Controller must be installed under the spa skirt)
Storage temperature: -25°C (-13°F) to 85°C (185°F)
Humidity: up to 85% RH, non condensing

Mechanical:

Weight: 4.76 kg (10.5 lbs)
Dimensions (W x H x D):
Chassis: 441.5x298.5 x129 mm (17.38" x 11.75" x 5.1")

UL/CSA Standards:

UL 1563 Fifth Ed.
UL File: E182156
CSA No. 22.2 - 218.1-M89.

TUV Standards:

EN/IEC 60335 - 2 - 60: 2003/2002 - EN/IEC 60335 - 1: 2002/2001
(incl. Corr. & Am. up to 2004)
EN55014-1
EN55014-2
EN61000-3-2
EN61000-3-3

The in.xe.ce is lab tested to IPx5 enclosure protection levels.

Keypads available for the in.xe:

in.k200 (LED display, 4 keys, 7 light indicators)
in.k219 (LED display, 4 keys, 7 function icons)
in.k235 (LED display, 6 keys, 8 function icons)
in.k400 (LCD display, 6 keys, 10 function icons)
in.k450 (LCD display, 6 keys, 10 function icons)

Interface connections:

communication link (in.stick or in.watch)